Please enable JavaScript to view this site.

Navigation: Quickstart Guides > VSAM Quickstart

VSAM Publisher Configuration

Scroll

This section guides you through the following tasks:

1.Define a new VSAM Publisher

2.Register the VSAM files to be published

3.Generating JCL to run the Publisher in standalone batch mode

4.Register the Publisher  agent with the Daemon

5.Prepare the Publisher to run as a started task

Management of the VSAM Publisher is performed via Publishers (option 3).

V4.00---------------------- Connect CDC SQData Main Menu ---------------------

Option ===>                                                                    

                                                                               

 Select One of the Following Options and Press ENTER                           

                                                                               

  0  Defaults                     Set Session Parameters                       

                                                                               

  1  Utilities                    Utilities                                    

                                                                               

  2  Daemons                      Manage Daemons                               

                                                                               

  3  Publishers                   Capture/Publisher Management                 

                                                                               

  4  Logstreams                   View/Manage z/OS Logstreams                  

                                                                               

  5  Reserved                     Reserved for Future Use                      

                                                                               

  6  IMS Log Capture Agents       IMS Log Based Data Capture Agents            

                                                                               

  7  Capture XPARMs               IMS Data Capture Exit XPARM Configuration    

                                                                               

  8  Master Controllers           Master Controller Configuration              

                                                                               

  X  EXIT                         Exit                                         

Select option 3 from the Connect CDC SQData menu and press ENTER to get started with this section.